Intelligent heating. Exceptional comfort.

Comfort, engineered intelligently.

Advanced heating and cooling solutions designed around your home, your comfort and your future.

0yrs

Engineering Niagara comfort

0

Systems commissioned

0min

Median emergency arrival

0.0/5

2,140 verified reviews

Cold-climate heat pumps

Condensing furnaces

Ductless zoning

Commissioning reports

Whole-home air quality

24/7 emergency dispatch

Cold-climate heat pumps

Condensing furnaces

Ductless zoning

Commissioning reports

Whole-home air quality

24/7 emergency dispatch

ST. CATHARINES · 4.2°C · RH 71%

38 TECHNICIANS IN FIELD

MEDIAN ARRIVAL · 47 MIN

COP TODAY · 3.1 AVG

11,480 SYSTEMS COMMISSIONED

NIAGARA-ON-THE-LAKE · 3.8°C

REBATES PROCESSED · $4.2M

WELLAND · 4.6°C · WIND 18 KM/H

ST. CATHARINES · 4.2°C · RH 71%

38 TECHNICIANS IN FIELD

MEDIAN ARRIVAL · 47 MIN

COP TODAY · 3.1 AVG

11,480 SYSTEMS COMMISSIONED

NIAGARA-ON-THE-LAKE · 3.8°C

REBATES PROCESSED · $4.2M

WELLAND · 4.6°C · WIND 18 KM/H

02 — Heating & cooling systems

Three platforms.
One standard of precision.

We specify, install and commission a deliberately short list of equipment we have tested through twenty Niagara winters. Choose a platform to see how it performs.

Up to 98% AFUE modulating gas heat, sized by room-by-room load calculation — never by rule of thumb.

Efficiency
96–98% AFUE
Modulation
40–100%
Sound
42 dBA
Warranty
12 yr parts
Explore Condensing Furnaces
Clean mechanical room with modern heating equipment and copper piping

01

Field-verified installation · Niagara Peninsula

03 — Interactive climate model

Watch a house breathe through a Niagara winter.

Drag the outdoor temperature. Toggle intelligent zoning. See how load, airflow and room-to-room balance respond in a modelled 2,000 ft² two-storey home.

Section A–A · Modelled residence · Fonthill, ON

Heating · 100% load

PRIMARY SUITE20.9°BEDROOMS20.8°LIVING & KITCHEN21.1°STUDY21.0°LOWER LEVEL20.9°AHU-1ODU · -12°C
-12°C
−28 · Jan record34 · Jul humidex
21°C
Mode
Heat
Room spread
0.3°C
Selected
Living & kitchen
Zone temp
21.1°C

Illustrative thermal model for demonstration only. Click any room in the section drawing.

04 — Energy intelligence

−$1,184

Estimated annual saving moving a 2,000 ft² 1990s home from a 78% furnace to a dual-fuel heat pump.

Our simulator models six system types against your home, your rates and Niagara’s heating degree days — then shows exactly which assumptions move the answer.

Open the Energy Simulator

Illustrative estimate · not a quote

SystemAnnual operating costEst.

Standard furnace · 78%

$2,960

High-efficiency furnace · 96%

$2,440

Air-source heat pump

$2,110

Cold-climate heat pump

$1,860

Dual-fuel hybrid

$1,776

3,820

Heating degree days · St. Catharines

−38%

Modelled CO₂e reduction

6.8 yr

Simple payback after rebates

04b — Thermal diagnostics

See where your heat escapes.

Every assessment includes an infrared survey. Drag the scanner across the house to reveal what our cameras see before we size a single piece of equipment.

Modern white house with patio in the evening

Window frame · 14.8°C loss

Roof line · attic bypass

Wall · R-24 OK

VisibleInfrared · FLIR E96

Scan 45% · Surface ΔT 11.6°C · Outdoor −6°C

Book a thermal assessment

05 — Technology & engineering

We draw it before we drill it.

Every Precision Climate installation begins as a set of measured drawings: heat-loss calculations per room, duct static pressure, airflow targets and a commissioning sheet you keep forever.

  • CSA F280 room-by-room heat lossE/01
  • Duct static pressure & airflow mappingE/02
  • Refrigerant charge by superheat & subcoolE/03
  • Combustion analysis & CO verificationE/04
  • Remote performance monitoring (opt-in)E/05
DWG PC-2026-0418 · Mechanical schematicScale NTS · Rev C
A-COIL · 3 TONFURNACE · 96% AFUE · 60K BTUODU · CCHP · HSPF2 10.2SUPPLY 44°C · 1,150 CFMRETURN 20°C · 0.42 IN.WCREFRIGERANT LINESET 3/8″ · 7/8″123

01 · HEAT EXCHANGER

Stainless secondary exchanger captures latent heat from flue gas.

02 · ECM BLOWER

Variable-speed motor holds target CFM as filters load.

03 · INVERTER COMPRESSOR

Ramps 20–120% to match load; hands off to gas below −15°C.

  1. PHASE 01

    Measure

    Blower-door estimate, envelope survey, existing duct test.

  2. PHASE 02

    Model

    Load calculation, equipment sizing, cost and carbon scenarios.

  3. PHASE 03

    Install

    Single-day swap for most homes. Floors protected, site left clean.

  4. PHASE 04

    Commission

    Measured results documented in your Customer Portal.

05b — Field journal

A week on the road with our crews.

Real job sites across the Niagara Region. Click any frame to open the full journal.

Calm contemporary living room with sea view

“Comfort is not a temperature. It’s the absence of noticing.”

— Daniel Moreau, P.Eng., Founder

07 — Why Precision Climate

Four promises, written into every contract.

  1. i.

    Fixed, itemised pricing

    The number on your proposal is the number on your invoice.

  2. ii.

    Licensed employees only

    No subcontractors. Every technician holds G2 gas and 313D refrigeration licences.

  3. iii.

    Measured performance

    If commissioned airflow or efficiency misses spec, we return at no cost.

  4. iv.

    10-year labour warranty

    On every system we install and maintain annually.

08 — Service coverage

Twelve municipalities. One dispatch floor.

Technicians are stationed in four depots across the Peninsula, so the nearest licensed tech is rarely more than 25 kilometres away.

Selected

St. Catharines

Median ETA
32 min
Techs based
6
Homes served
3,120
View all service areas

Lake Ontario

Lake Erie

Niagara River

Schematic map, not to scale. ETAs are illustrative sample data.

09 — Customer trust

4.9

2,140 verified reviews · Google & HomeStars

Laura Kimura at home

“They showed up with a drawing of our house and a number for every room. The upstairs bedroom has been cold for fifteen years — it isn’t anymore.”

Laura KimuraFonthill · Cold-climate heat pumpInstalled Nov 2025